  • Voice King Alarm Host Programming Graphic Tutorial

    Release time: 2015-08-21 16:39

    Voice King Alarm Host Command Address Programming Instructions


    [ Content summary ] The following is a detailed description of the instruction address programming. After the network alarm operator purchases the voice king alarm host, he does not understand how to program. You can refer to the following programming method. This programming instruction can help the alarm operator to use voice more easily Wang alarm host.

    Voice king alarm host function description


    Condition: To program all the following addresses, the host must be in a programming state. After entering the programming state, all addresses can be programmed at one time and then exited, and can be programmed in multiple times.

    I. Command address 01 ~ 08: Setting of zone attributes of zones 1 ~ 8

    (1) Defense zone number: 01 ~ 08 means 1 ~ 8 defense zones;

    (2) Zone types: 0 is the instant alarm zone; 1 is the delayed alarm zone; 4 is the 24-hour zone; 5 is the internal zone; 6 is the intelligent zone; 7 is the permanent bypass zone; 8 is the access control arming / disarming zone ; 9 is the access control arming / disarming zone; the factory value of zones 1 to 8 is 0: instantaneous alarm zone.

    (3) Siren status: 0 for silent alarm, 1 for audible alarm, 2 for doorbell audible zone, 3 for doorbell audible siren zone, factory value is 1.

    (IV) Input format: zone number (2 digits) + zone type (1 digit) + alarm status (1 digit) + #

    Second, the command address 09 ~ 16: 9 ~ 16 zone defense zone settings

    (1) Zone number: 09 ~ 16 means 9 ~ 16 zone;

    (2) Zone type: 0 is the instantaneous alarm zone; 1 is the delayed alarm zone; 4 is the 24-hour zone; the factory value is 0: the instantaneous alarm zone.

    (3) Siren status: 0 is silent alarm, 1 is audible alarm, factory value is 1.

    (IV) Input format: zone number (2 digits) + zone type (1 digit) + alarm status (1 digit) + #

    Third, instruction address 20: wireless detector learning

    (I) Input format: 20 + AB + #

    (1) AB = 01 ~ 08 means that the wireless device will learn the first position of the defense zone 1 ~ 8 of the alarm host;

    (2) AB = 21 ~ 28 means learning the wireless device to the second position of the defense host 1 ~ 8 zone;

    (3) AB = 11 ~ 18 means that the wireless device will learn the first position of the defense zone 9 ~ 16 of the alarm host;

    (4) AB = 31 ~ 38 means that the wireless device will learn the second position of the defense zone 9 ~ 16 of the alarm host;

    (4) AB = 51 ~ 54 means learning 1-4 patrol remote controllers to the alarm host for patrol personnel patrol;

    Pairing code: Enter programming, and press # to confirm after entering the address 20 and location zone number. The corresponding zone light is on and the buzzer emits two long "drops". Press the remote control or trigger the detector to emit a signal After the host receives the signal, the buzzer will emit two long "didi" sounds, indicating that the code is successful. Press # to indicate that the learning is complete, and the corresponding zone indicator will go out. Steps.

    4. Command address 21: delete the information of the wireless detector from the host;

    (1) Defense zone code: 01 ~ 08;

    Explanation: 01 corresponds to 01 and 09 zones, 02 corresponds to 02 and 10 zones, 03 corresponds to 03 and 11 zones, 04 corresponds to 04 and 12 zones, 05 corresponds to 05 and 13 zones, 06 corresponds to 06 and 14 zones, and 07 corresponds to 07 and 15 zones. The 08 corresponds to the 08 and 16 zones. The zone numbers are the same as those learned. In this way, the remote control or wireless detector memory on the zone is deleted from the host.

    (2) Input format: 21 + zone code (2 digits) + #

    5. Instruction address 25: 8-channel relay linkage module control output;

    (1) Zone number: 01 ~ 16 indicates the host's zone 1 ~ 16, and the output relay port number 01 ~ 08 indicates the 8-way relay linkage module ports 1 ~ 8;

    Explanation: Any of the zone alarms in the host's 1 ~ 16 zones can be programmed to control any of the 8 relay relay inputs. Now, the 15th zone alarm is required to output the 4th port of the relay, which is directly input under programming state: 25 + 15 + 04 + #

    (2) Input format: 25 + zone number (2 digits) + output relay port number (2 digits) + #

    6. Instruction address 30: Modify installer code

    Input format: 30 + new password (6 digits) + #

    Need to change the installer code to 686868, and enter directly in the programming state: 30 + 686868 + #

    7. Instruction address 31: Host center network access number

    Input format: 31 + 4 digits user number + #

    Need to change the host center network access number to 5678, and enter directly in the programming state: 30 + 5678 + #

    Eight, instruction address 32: delete the host center network access number

    Input format: 32 + #

    Need to clear the host network access number, directly enter the programming state: 32 + #

    Schematic diagram of communication programming of control panel


    Nine, instruction address 41: siren sound time setting

    Input format: 41 + XY + #

    You need to set the siren to sound for 3 minutes, and the sirens will sound 3 tones during arming. Directly enter the programming state: 41 + 33 + #

    X. Instruction address 42: Set in and out delay time

    Input format: 41 + ABCD + #

    AB is the exit delay time: 00 ~ 99 seconds;

    CD is alarm delay time: 00 ~ 99 seconds;

    It is necessary to set the host access delay time to 60 seconds, the alarm delay to 10 seconds, and directly input in the programming state: 42 + 6010 + #

    11. Command address 43: Delay time setting of wired intelligent zone

    Input format: 43 + time + # factory value is 45 seconds

    Time: 10 ~ 90 seconds;

    It is necessary to set the smart zone time to arm for 10 seconds, and directly input in programming state: 43 + 10 + #

    12. Instruction address 44: Wired zone response time setting

    Input format: 44 + time + # default time: 30 factory value is 600ms

    Time: 01 ~ 30 seconds;

    Need to set the response time of the wired zone to 400ms, and enter directly in the programming state: 44 + 20 + #

    13. Command address 45: Force arming on / off

    Input format: 45 + status + # factory value is 0

    0 means force arming is off;

    1 means forced arming is on;

    You need to turn on the forced arming function, and enter directly in the programming state: 45 + 1 + #

    14. Command Address 46: Keyboard Shortcut Arm On / Off

    Input format: 46 + status + # factory value is 0

    0 means that the shortcut key is disabled;

    1 indicates that the shortcut key is armed;

    Need to turn on the arming function of the shortcut key, and enter directly in the programming state: 46 + 1 + #

    15. Command address 47: Telephone line fault detection on / off, AC power failure / recovery, and low battery voltage detection time

    Input format: 47+ XYZ + # The default value is 011

    Need to open the host phone line fault detection, AC power upload and battery voltage low function, directly enter the programming state: 47 + 111 + #

    16. Command address 49: Delay time before dialing

    Input format: 49+ time + # factory value is 2 seconds

    Status: 0 ~ 5 represents the delay time before the host dials, 0 ~ 5 is equal to 0 ~ 5 seconds

    Explanation: Set the waiting time before the host dials, which is the time that the host waits before dialing

    17. Command Address 50: Setting and Deleting the Telephone Number of the Alarm Center

    Input format: 50 + phone number + #

    Delete input: 50 + #

    Set the telephone number of the 110 alarm center of the 50 address to the alarm center: 2600000, and directly input in the programming state: 50 + 2600000 + #

    Delete the 50-address phone number, and enter directly in the programming state: 50 + #

    18. Command address 51 ~ 54: Set and delete 1 ~ 4 groups of phone numbers

    Input format

    The first set of phone number settings: 51 + phone number + #

    Delete the first group of phone numbers: 51 + #

    The second set of phone number settings: 52 + phone number + #

    Delete the second set of phone numbers: 52 + #

    The third set of phone number settings: 53 + phone number + #

    Third group phone number deleted: 53 + #

    The fourth group of phone number settings: 54 + phone number + #

    Delete the fourth group of phone numbers: 54 + #

    19. Command address 60: GPRS upload port number setting

    Input format: 60 + 4-digit port number + #

    Set the host upload port number to 2012, the program status is in love, directly enter: 60 + 2012 + #

    Twenty, instruction address 61: 51 ~ 54 alarm phone attribute modification

    Input format: 61 + ABCD + #

    (1) The address 51 is "Zero Call" arming line;

    (2) The address of 52 is the "zero toll" disarming special line;

    (3) 53 and 54 are alarm dialing user's mobile phones, and directly input in programming state: 61 + 4500 + #

    Twenty-one, the command address 62: 1 ~ 4 defense zone, choose to dial the phone number 51 ~ 54

    Input format: 62 + ABCD + #

    (1) Dial 52 calls after the alarm in the 1 zone;

    (2) Dial No. 51 after the alarm in 2 defense zones;

    (3) Dial No. 53 after the 3 zone alarm;

    (4) Dial 51 and 52 after the alarm in 4 zones, and directly input in programming state: 62 + 2135 + #

    22. Instruction address 63: Select the phone number 51 ~ 54 after the alarm in zone 5 ~ 8

    Input format: 63 + ABCD + #

    (1) Dial 51 on the 5th zone alarm;

    (2) Dial 52 calls after alarming in 6 zones;

    (3) Dial 53 on the 7th alarm zone;

    (4) Dial 51 and 52 after the alarm in the 8th zone. In the programming state, directly input: 62 + 1235 + #

    22. Instruction address 70: Report transmission settings and SMS sending method

    Input format: 70 + status + #

    Set only the alarm information transmission center, all events send text messages, directly enter in the programming state: 70 + 2 + #

    Twenty-three, instruction address 71: remote setting of telephone remote control

    Input format: 71+ status + #

    Remotely control the host computer by telephone, directly input in programming state: 71 + 1 + #

    Steps

    (1) Programming opens the remote control and remote programming function of 71 address;

    (2) Using a mobile phone or another phone, dial the phone connected to the host, hear the ringback tone set at address 72, and then hear a long beep, and then the voice prompt "Please enter the password" means that The alarm host has been connected to the outside line;

    (3) Enter the user password from the telephone keypad to verify the host password;

    (A) If the user's password is incorrectly entered, two short “beep” sounds can be heard on the phone, and the password is incorrectly disconnected three times;

    (B) If the password is correct, a voice announcement can be heard on the phone, indicating that the host has entered the state of receiving user instructions. The voice announcement is as follows, as shown in the following figure:

    Host programming operation instruction diagram

    24. Instruction address 72: Setting of the number of remote control ringing times and the number of dialing times of the alarm host

    Input format: 70 + number of rings + number of dials + #

    Ringing times: 1 ~ 8 times

    Represents the number of times the phone rings before the host automatically connects during remote control;

    Dialing times: 1 ~ 9 times

    It means that the host can dial the maximum number of times when the host cannot dial the preset phone number or does not receive the user confirmation tone after the alarm;

    Need to set the phone to ring 6 times when remotely controlled, 5 times to dial when no one answers the phone, directly input in programming state: 72 + 65 + #

    Twenty-five, instruction address 73: close / open setting for all wired zones

    Input format: 73 + status + #

    status

    0 means all wired zones are closed;

    1 means all wired defense zones are open, using wire loop;

    2 means that all wired defense zones use EOL2.2K balancing resistors;

    The host only uses wireless zones, close all wired zones, and enter directly in programming state: 73 + 0 + #

    26. Instruction address 731 ~ 738: 1 ~ 8 single wired zone close / open setting

    Input format: 731 ~ 738 + status + #

    status

    0 means all wired zones are closed;

    1 means all wired defense zones are open, using wire loop;

    2 means that all wired defense zones use EOL2.2K balancing resistors;

    The host only uses wireless zones, close all wired zones, and enter directly in programming state: 73 + 0 + #

    The above is the programming instructions for the voice king alarm host. If you still do not understand and need an alarm operator, you can click the link below to download it for free

    Voice King alarm host programming detailed tutorial Word format file download link address: http://pan.baidu.com/s/1eQlQWU2 Password: hhhr Download and save to your computer hard drive.

    like
    (9)
    100%
    Step on it
    (0)
    0%

    90% of people also read the following article

  • Network alarm system WeChat disarming function tutorial
    For many new and old users, I don't know how to use the WeChat arming and disarming function in the mobile APP, so here, I will explain the operation steps in detail to everyone ... [View Details]
  • The best choice of door-to-door anti-theft alarm
    When the alarm operator installs the alarm at the door, not only needs to consider whether the user is suitable for the requirements of anti-theft, but also needs to consider the installation location and the overall beauty and security ... [View Details]
  • Physical store marketing planning implementation system solution
    The latest networked alarm system marketing plan in 2016, specifically to solve the problem of operators who have newly joined the networked alarm industry in the physical store to achieve greater profits in marketing, and ... [View Details]
  • Network alarm operation company service content
    The service content of the operating company mainly provides users with the most secure and high-quality networked alarm services, not only for security protection services, but also for users ... [View Details]
  • How about the infrared detection function of the burglar alarm system
    The function of the infrared detector needs to be used in the burglar alarm system, that is, it needs to be used with the alarm host in the burglar alarm system ... [View Details]
  • Voice King Alarm Host Programming Graphic Tutorial
    The network alarm operator does not understand how to program after purchasing the voice king alarm host. So provide free programming detailed tutorial download, programming instructions can help operators ... [View Details]